Gas boilers "Gepard": characteristics, device, installation and reviews. Gas double-circuit boiler Cheetah from Protherm Proterm Cheetah 23 mtv technical specifications

Description of Protherm Cheetah

Wall-mounted gas double-circuit boilers with a capacity of 11 kW for heating and hot water preparation in a steel plate heat exchanger.
Are intended for installation in apartments, houses and country houses. Boilers are heating appliances of increased comfort, they are easy to use and maintain.
Using the liquid crystal display, you can continuously receive information at any time during the operation of the boiler. The display allows you to constantly monitor the entire process.
Boiler models Protherm Cheetah 11 MOV and 23 MTV are equipped with a coaxial flue gas system and do not require connection to a chimney, which allows them to be installed in rooms where there is no stationary chimney or its installation is very difficult or impossible due to various reasons.

Technical description
Double-circuit gas boiler
Open (MOV model) / closed combustion chamber (MTV model)
Power 11.0 kW
Efficiency 90.3% (MOV models) / 93.2 (MTV models)
Automatic burner flame modulation
Independent regulation of thermal loads of the circuits of the heating system and hot water supply
Steel plate DHW heat exchanger
Hot water preparation 11.0 l/min. (at ∆t=30 °C)
Boiler control with built-in microprocessor
Automatic diagnostics of boiler operation
Liquid crystal display which displays the temperature and pressure of the coolant in the heating system, indication of malfunctions, as well as an indication of the need for preventive maintenance of equipment
Control mode "WINTER-SUMMER"
Control mode "COMFORT"
Ability to work with weather-dependent automation
Flame detection
Frost protection
overheat protection
Circulation pump anti-blocking system
Chimney draft control
Built-in make-up valve for filling the heating system
Built-in circulation pump with automatic air vent
Possibility of work on the main and liquefied gas
Warranty 2 years

Designations of wall-mounted gas boilers PROTHERM Cheetah:
11 - boiler power.
MOV– open combustion chamber, hot water heating in flow mode.
MTV– closed combustion chamber, hot water heating in flow mode.

Description of Protherm Cheetah

Wall-mounted gas double-circuit boilers with a capacity of 11 kW for heating and hot water preparation in a steel plate heat exchanger.
Are intended for installation in apartments, houses and country houses. Boilers are heating appliances of increased comfort, they are easy to use and maintain.
Using the liquid crystal display, you can continuously receive information at any time during the operation of the boiler. The display allows you to constantly monitor the entire process.
Boiler models Protherm Cheetah 11 MOV and 23 MTV are equipped with a coaxial flue gas system and do not require connection to a chimney, which allows them to be installed in rooms where there is no stationary chimney or its installation is very difficult or impossible due to various reasons.

Technical description
Double-circuit gas boiler
Open (MOV model) / closed combustion chamber (MTV model)
Power 11.0 kW
Efficiency 90.3% (MOV models) / 93.2 (MTV models)
Automatic burner flame modulation
Independent regulation of thermal loads of the circuits of the heating system and hot water supply
Steel plate DHW heat exchanger
Hot water preparation 11.0 l/min. (at ∆t=30 °C)
Boiler control with built-in microprocessor
Automatic diagnostics of boiler operation
Liquid crystal display which displays the temperature and pressure of the coolant in the heating system, indication of malfunctions, as well as an indication of the need for preventive maintenance of equipment
Control mode "WINTER-SUMMER"
Control mode "COMFORT"
Ability to work with weather-dependent automation
Flame detection
Frost protection
overheat protection
Circulation pump anti-blocking system
Chimney draft control
Built-in make-up valve for filling the heating system
Built-in circulation pump with automatic air vent
Possibility of work on the main and liquefied gas
Warranty 2 years

Designations of wall-mounted gas boilers PROTHERM Cheetah:
11 - boiler power.
MOV– open combustion chamber, hot water heating in flow mode.
MTV– closed combustion chamber, hot water heating in flow mode.

The Cheetah gas boiler is manufactured by Proterm. In principle, it has proven itself well in the Russian market, but at first there were problems with these devices. Some boilers had problems with the software and the work of the "brains". Over time, manufacturers took this into account, and now the occurrence of errors is rather an exception to the rule. There are no complaints about the components, their quality does not raise questions.

Boiler Cheetah - double-circuit

Let's start with the fact that the Cheetah gas boiler is double-circuit. This means that this unit can simultaneously heat the coolant for the heating system, as well as water for hot water supply. This is possible thanks to two heat exchangers.

Heat exchangers are installed in the combustion chamber above the flame - these are coils through which water flows. They are made of copper, to increase the heat exchange area on the coil there are fins. Therefore, in the short time that the liquid is in the heat exchanger, it has time to heat up to the level set by the user.

For heating, the temperature of the heat carrier in the entire system is set, and for DHW, the degree of heating in flow mode. The maximum allowable water temperature for hot water is 65 degrees. At a flow rate of 11.4 l / min, the temperature delta is 30 degrees.

For example, if the make-up from the water supply comes with a temperature of 15 degrees, then the boiler can produce 11.4 liters of water per minute with a temperature of 45 degrees. Boilers Cheetah are equipped with a hot start function. In just 2 seconds, the device heats running water to the required level. That is, when opening the tap, you do not need to drain the water that has not had time to heat up.

The Cheetah boiler has two modes of smoke extraction

The line includes two models of heaters:

  • with natural smoke extraction 23 MOV;
  • with forced smoke extraction 23 MTV.

This information about the Proterm Cheetah boiler can be found in the instructions. In units with natural draft, the combustion chamber is open, that is, leaky. The air for the flame in such heaters comes from the room in which it is installed (more precisely, it is hung on the wall, since they are all wall-mounted). This is neither good nor bad. You just need to ventilate the room more often. For such boilers, a stationary chimney is needed. About, , We have already written, so we will not repeat ourselves.

It does not matter if it is not possible to install a stationary chimney, because. for units with forced smoke extraction, it is not needed (see). Such boilers Cheetah are called coaxial. Smoke comes out through . She is taken outside right through the wall, which is very convenient. The advantage of a coaxial chimney is that it not only removes smoke, but also supplies oxygen to the combustion chamber. By the way, it is hermetically sealed in such units.

Considering, you need to take care of its reliable fixation.

Steel is much lighter, but it also accumulates heat worse.

The circulation of gases in the coaxial chimney (in both directions) is forced. The fan installed above the combustion chamber is responsible for this. It works from the network, so these boilers consume more electricity.

Complete set and technical characteristics of boilers Cheetah

The gas boiler Cheetah, regardless of the model, is connected to the mains. Wherever you live, power surges or blackouts always happen. Therefore, in order for the operation of heating and hot water to be uninterrupted, it is recommended to install (an uninterruptible power supply). The package of the boiler Cheetah includes:

  • two-stage circulation pump;
  • expansion tank 5 l;
  • microprocessor with the ability to connect an external temperature sensor and an eBus connector;
  • electrical protection IPX4D.

P, according to the law, is prohibited. The project needs to be redone.

There are different types: manual and automatic.

For DHW there is a make-up pipe. It can also be used to fill the heating system. On the front part there is an LCD display. Specifications:

  • power: min. 9 kW, max. for 23 MOV 23 kW, and for 23 MTV 24.6 kW;
  • Efficiency for 23 MOV 89.5%, and for 23 MTV - 91.1%;
  • flue gas temperature 110 degrees;
  • maximum coolant temperature - 83 degrees, hot water supply - 65 degrees;
  • maximum working pressure of heating - 3 atmospheres, hot water supply - 10 bar;
  • power consumption for 23 MOV is 92 Wh and for 23 MTV is 156 Wh.

Both boilers have the same dimensions (height / width / depth) 74x41x31 cm. Weight without water - 13 kg.

You can pick up the purchased goods yourself or use the delivery service in Moscow and the Moscow region. Having placed an order today, tomorrow you will receive it at your disposal. If necessary, you can use the service of prompt delivery and receive products today.

Delivery to the entrance (check with the manager about the possibility of raising to the floor)

Delivery is made daily from 9 am to 9 pm including weekends and holidays.

Specify exact terms of delivery at the manager!

Pickup points

Delivery cost in Moscow and the Moscow region:

  • Within the Moscow Ring Road - from 0 to 500 rubles, (Individual shipping cost is indicated in the product card)
  • Outside the Moscow Ring Road up to 10 km - 700 rubles,
  • Outside the Moscow Ring Road further 10 km - 700 rubles + 30 rubles for each kilometer.
  • In the regions, delivery by a transport company (calculated individually).

Shipping cost for

km from MKAD

700 rub.

Unloading of bulky goods is carried out by the forces and means of the customer.

Money is transferred directly to the courier upon receipt of the goods. This method is the most popular among buyers due to the simplicity and ease of calculation.

Payment by bank card to the courier upon receipt

Couriers have a portable bank terminal available, which allows Teplovod-Service customers to pay for goods with bank plastic cards (check with the manager about the possibility of paying with a bank card).

Payment by credit card on the site

To select payment by bank card on the "Cart" page, select the item "Payment by bank card on the site".

Payment is made through PJSC SBERBANK using Bank cards of the following payment systems:


After clicking on the "ONLINE PAYMENT" button, you will be redirected to the payment gateway of Sberbank of Russia OJSC to enter your card details.

Please prepare your plastic card in advance. Additionally, you need to enter the full name, email, contact phone number, as well as the reservation number to identify the payer. The connection with the payment gateway and the transfer of information is carried out in a secure mode using the SSL encryption protocol.

If your bank supports the technology of secure online payments Verified By Visa or MasterCard Secure Code, you may also need to enter a special password to make a payment. You can check the methods and the possibility of obtaining passwords for making Internet payments at the bank that issued the card.

This site supports 256-bit encryption. The confidentiality of the reported personal information is provided by Sberbank of Russia OJSC. The entered information will not be provided to third parties, except as provided by the legislation of the Russian Federation. Payments by bank cards are carried out in strict accordance with the requirements of Visa Int payment systems. and MasterCard Europe Sprl.

When paying by credit card, interest is not charged.

Payment is a transfer of funds from the buyer's current account to the seller's account, we work on a common taxation system with VAT. Delivery of goods is carried out after the receipt of funds to the account of the company "Teplovod-Service". This method is used in the calculations of legal entities.

Our details

    Limited Liability Company "Teplovod-Service"

    OGRN: 1105003006162

    TIN: 5003088884

    Checkpoint: 500301001

    BIC: 044525225

    Bank: PJSC Sberbank of Russia

    R/s: 40702810838060011732

    K/s: 30101810400000000225

    Jur. the address: 142718, Moscow region, Leninsky district, Bulatnikovskoe rural settlement, Varshavskoye highway, 21 km., office B-6

Special conditions

    For goods with the status "On order" worth up to 100,000 rubles. no prepayment required.

    For goods with the status "On order" over 100,000 rubles. a 30% deposit is required.

  • For any goods sent by a transport company, 100% payment is required.

Reviews about the product «Wall-mounted double-circuit boiler Protherm Cheetah 23 MTV turbo»

There are no reviews for this product yet. Your review will be the first!

European gas heating equipment has long been not only competitive in the world market, but has also taken a leading position in some countries. For example, Czech gas boilers Proterm Gepard are popular in Europe and the countries of the former USSR.

The principle of operation and technical features of the equipment

Cheetah boilers are produced with a capacity of 23 kW, while they are able to provide heating and hot water to small residential buildings, apartments in high-rise buildings and small industrial enterprises. The heating of water and the heat carrier of the heating system takes place in a heat exchanger made of steel. The lamellar form of the heat exchanger increases the area of ​​absorption of heat produced as a result of burning natural gas.

The residual products formed as a result of gas combustion are removed through a coaxial chimney supplied with the Proterm Gepard 23 MTV gas boiler, or purchased separately. The flow of oxygen into the closed combustion chamber is produced by a forced ventilation system through the external channel of the coaxial chimney.

For the necessary control and management of the boiler, a small LCD display is provided, located on the front surface. The display clearly shows the current work program and additional indicators that monitor the normal operation of all components during self-diagnosis. These include:

  1. Protection against freezing of the coolant in the boiler, automatically turning on the circulation pump and the burner when the temperature drops below the set parameters.
  2. Overheating protection allows you to protect the gas boiler Protherm Cheetah 23 MTV from burnout of the furnace.
  3. Control of gas combustion in the combustion chamber, automatically shutting off the gas supply if the burner goes out.
  4. A draft sensor that turns off the gas supply to the boiler in the event of a lack or unstable draft.
To improve technical performance and the ability to work in closed heating systems, the Protherm Gepard 23 MTV boiler is equipped with a built-in circulation pump. To remove air from the system, the pump has a bleed valve that automatically eliminates air pockets. The pump has an additional option to protect the circulation pump from shutdown or blockage.

The modulating burner makes it possible to smoothly adjust the heating of water and coolant, the load on both circuits can be changed separately. The increase in power and the switching of the boiler operating modes to DHW occurs as soon as the hot water tap is opened. The boiler is capable of supplying up to 11 liters of water per minute, heated to a temperature of +60C, provided that the temperature of the incoming water is around +30C.

If necessary, wall-mounted gas boilers Protherm Cheetah 23 MTV can be equipped with a climate control system and weather-dependent equipment that can automatically change the heating temperature when the weather conditions change.

Advantages and disadvantages

There are practically no drawbacks to wall-mounted gas boilers Proterm Gepard23 MTV. The only thing - like other similar equipment, Cheetah 23 is not able to work without electricity. The advantages of heaters are much more:
  1. Natural or household gas is a relatively cheap type of fuel available in any region through central gas distribution lines or pumped into cylinders and.
  2. The level of harmful emissions is minimal and mainly consists of carbon dioxide.
  3. The compact dimensions of the equipment allow it to be mounted in rooms with a limited area.
  4. Full automation of work processes makes it possible to operate equipment without human intervention for a long time.
  5. Built-in security systems ensure reliable operation of the boiler throughout all operational periods.

Simplified model

A cheaper model of equipment can be considered a gas wall-mounted boiler Protherm Cheetah 23 MOV with an open combustion chamber and natural exhaust of combustion products. This design eliminates the need to install a complex system with forced draft in the furnace and makes it possible to connect boiler equipment to a conventional low-temperature chimney, and not to a coaxial steam outlet. Otherwise, MOV series boilers do not differ from high-quality, technologically advanced boilers of the PROTERM MTV brand.
Loading...Loading...